summaryrefslogtreecommitdiff
blob: d1744af862bd9801c9eeb35a69649dbac6b2c103 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
# Copyright 1999-2014 Gentoo Foundation
# Distributed under the terms of the GNU General Public License v2
# $Id$

EAPI=3

inherit eutils linux-info flag-o-matic systemd

DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown"
HOMEPAGE="http://www.apcupsd.org/"
SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz"

LICENSE="GPL-2"
SLOT="0"
KEYWORDS="amd64 ppc x86 ~x86-fbsd"
IUSE="snmp +usb cgi nls gnome kernel_linux"

DEPEND="
	||	( >=sys-apps/util-linux-2.23[tty-helpers]
		  <=sys-apps/sysvinit-2.88-r4
		  sys-freebsd/freebsd-ubin
		)
	cgi? ( >=media-libs/gd-1.8.4 )
	nls? ( sys-devel/gettext )
	snmp? ( net-analyzer/net-snmp )
	gnome? ( >=x11-libs/gtk+-2.4.0:2
		dev-libs/glib:2
		>=gnome-base/gconf-2.0 )"
RDEPEND="${DEPEND}
	virtual/mailx"

CONFIG_CHECK="~USB_HIDDEV ~HIDRAW"
ERROR_USB_HIDDEV="CONFIG_USB_HIDDEV:	needed to access USB-attached UPSes"
ERROR_HIDRAW="CONFIG_HIDRAW:		needed to access USB-attached UPSes"

pkg_setup() {
	if use kernel_linux && use usb && linux_config_exists; then
		check_extra_config
	fi
}

src_configure() {
	local myconf
	use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=/usr/libexec/${PN}/cgi-bin"
	if use usb; then
		myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev= "
	else
		myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb"
	fi

	append-flags -fno-strict-aliasing

	# We force the DISTNAME to gentoo so it will use gentoo's layout also
	# when installed on non-linux systems.
	econf \
		--sbindir=/sbin \
		--sysconfdir=/etc/apcupsd \
		--with-pwrfail-dir=/etc/apcupsd \
		--with-lock-dir=/var/lock \
		--with-pid-dir=/var/run \
		--with-log-dir=/var/log \
		--with-nis-port=3551 \
		--enable-net --enable-pcnet \
		--with-distname=gentoo \
		$(use_enable snmp net-snmp) \
		$(use_enable gnome gapcmon) \
		${myconf} \
		APCUPSD_MAIL=/bin/mail \
		|| die "econf failed"
}

src_compile() {
	# Workaround for bug #280674; upstream should really just provide
	# the text files in the distribution, but I wouldn't count on them
	# doing that anytime soon.
	MANPAGER=$(type -p cat) \
		emake || die "emake failed"
}

src_install() {
	emake DESTDIR="${D}" install || die "installed failed"
	rm -f "${D}"/etc/init.d/halt

	insinto /etc/apcupsd
	newins examples/safe.apccontrol safe.apccontrol

	dodoc ChangeLog* ReleaseNotes
	doman doc/*.8 doc/*.5 || die "doman failed"

	dohtml -r doc/manual/* || die "dodoc failed"

	rm "${D}"/etc/init.d/apcupsd
	newinitd "${FILESDIR}/${PN}.init.2a" "${PN}" || die "newinitd failed"
	systemd_dounit "${FILESDIR}"/${PN}.service
	systemd_dotmpfilesd "${FILESDIR}"/${PN}-tmpfiles.conf

	if has_version sys-apps/openrc; then
		newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail || die "newinitd failed"
	fi

	# remove hal settings, we don't really want to have it around still.
	rm -r "${D}"/usr/share/hal

	# Without this it'll crash at startup. When merging in ROOT= this
	# won't be created by default, so we want to make sure we got it!
	keepdir /var/lock
	fowners root:uucp /var/lock
	fperms 0775 /var/lock
}

pkg_postinst() {
	if use cgi; then
		elog "The cgi-bin directory for ${PN} is /usr/libexec/${PN}/cgi-bin."
		elog "Set up your ScriptAlias or symbolic links accordingly."
	fi

	elog ""
	elog "Since version 3.14.0 you can use multiple apcupsd instances to"
	elog "control more than one UPS in a single box."
	elog "To do this, create a link between /etc/init.d/apcupsd to a new"
	elog "/etc/init.d/apcupsd.something, and it will then load the"
	elog "configuration file at /etc/apcupsd/something.conf."
	elog ""

	if [ -d "${ROOT}"/etc/runlevels/shutdown -a \
			! -e "${ROOT}"/etc/runlevels/shutdown/"${PN}".powerfail ] ; then
		elog 'If you want apcupsd to power off your UPS when it'
		elog 'shuts down your system in a power failure, you must'
		elog 'add apcupsd.powerfail to your shutdown runlevel:'
		elog ''
		elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m'
		elog ''
	fi
}